Troubleshooting the New User Interface
The problems below account for almost everything that goes wrong when setting the interface up for the first time. Work through the checks in order, they are ordered by how often each turns out to be the cause.
The interface is not reachable at all
/user/ shows the classic application's "not found" page, or the classic sign-in page.
Check the setting is actually
true.bashgrep '^UI_ENABLED' .oempro_envRecreate the containers, do not restart them.
bash./cli/octeth.sh docker:upWARNING
This is the single most common cause.
UI_ENABLEDis read by two containers: the interface, which reads the file from disk on every start, and the reverse proxy, which reads it from its own environment and only picks up a change when it is recreated. A plain restart updates one and not the other, and the symptom is exactly this: the proxy sends people to a container that answers "not found" for every page.Check the container is running.
bashdocker ps --filter name=oempro_ui
Every page shows a server error
Usually a blank page or a plain "server error" message, on every page including sign-in.
Build the assets.
./cli/octeth.sh ui:buildThe stylesheets and scripts are built at release time and shipped inside the release package. An install made from a source checkout has none, and every page fails to render without them.
TIP
If the build succeeds and pages still fail, check the container's log for the first error rather than the last:
docker logs oempro_ui 2>&1 | head -50The container starts but says the database is missing
The log shows a message naming the database and pointing at a command.
Create it.
./cli/octeth.sh ui:db-setupThe interface has its own database and no permission to create one, because it is deliberately never given administrator credentials for MySQL. The installer and the upgrade script normally create it for you, so seeing this means neither has run.
The container refuses to start and names Octeth's database
The log says the interface's database is Octeth's own database and it is refusing to start.
This is a safety measure doing its job. Set UI_MYSQL_DATABASE in .oempro_env to a separate name, oempro_ui by convention, then create it with ./cli/octeth.sh ui:db-setup.
DANGER
Do not work around this by making the two match. The interface's test suite rebuilds whatever database it is pointed at from scratch. Pointed at Octeth's own database, that destroys the entire install.
The logo or the tab icon is broken
Check the path starts with /ui/.
UI_BRAND_LOGO_MARK=/ui/images/brand/acme-mark.svgThe reverse proxy only forwards a fixed set of paths to the interface, and /ui/ is the one carrying its files. An image at /images/acme-mark.svg is handed to the classic application instead, which does not have it.
TIP
Confirm by opening the image address directly in a browser. If it displays or downloads, the path is right.
The same applies to the tab icon. A file at /favicon.ico is answered by the classic application, so the icon must also sit under /ui/.
A colour change did nothing
Check the value is quoted.
iniUI_BRAND_ACCENT="#2563EB"An unquoted
#is read as the start of a comment. The result is a value that looks correct in the file and is empty when read.Check the value is a valid hex colour of 3, 6 or 8 digits including the
#. Anything else is ignored and the built-in colour is used, so a typo shows up as a colour that did not change rather than as an error.If the sidebar or the signed-out panel did not change, that is expected. Those two have dark backgrounds and render their highlights in white regardless of your accent, because a dark accent would be invisible against them.
Charts still use the old colours
Expected. Charts use several colours to tell one data series from another, so they keep their own palette. Collapsing them to a single brand colour would make the series impossible to tell apart. The same applies to the interface's own emails and the invoice PDF, which carry fixed colours because email clients cannot read the mechanism that applies your palette to a web page.
The staff billing screens return "not found"
Billing is turned off. Set it on and recreate the containers:
BRAND_FEATURE_BILLING=trueWARNING
The setting does not start with UI_. UI_BRAND_FEATURE_BILLING has no effect.
A billing command runs and produces no output
Same cause. Every billing command deliberately does nothing when billing is off.
A customer cannot be placed in a user group
The reconcile job reports an error for that account, or a plan change fails.
- Check the plan has a Default group link on the Catalog screen. Every plan needs one.
- Check the account-wide groups under Staff, Billing settings, User groups.
- Open the Billing health screen, which lists exactly which links are missing.
Nobody is ever suspended for not paying
The suspended user group is not set. Set it under Staff, Billing settings, User groups, or give the plan its own suspended link on the Catalog screen. Payments keep working without it, which is why this can go unnoticed for a long time.
Payments succeed but Octeth does not update
The webhook is not arriving.
- Check the address in your processor's dashboard includes
/ui/, for examplehttps://your-domain/ui/webhooks/stripe. - Check the signing secret saved on the Payment gateways screen matches the one your processor shows.
- Open the Billing health screen and look at the webhook section for recent deliveries.
Password reset emails never arrive
The interface writes its emails to a log by default rather than sending them. Set a real mail server:
UI_MAIL_MAILER=smtp
UI_MAIL_HOST=smtp.example.com
UI_MAIL_PORT=587
UI_MAIL_FROM_ADDRESS=no-reply@acmemail.comThe interface shows numbers that are clearly fictional
Demo mode is on. Set UI_DEMO_MODE=false in .oempro_env and restart the interface container. Demo mode replaces the live connection with a fictional dataset for screenshots, and it looks entirely normal while it is on.
INFO
Demo mode only takes effect when APP_ENV is local or testing, so this cannot happen on a production install.
Everyone was signed out and nothing decrypts
UI_APP_KEY changed. If you still have the old value, put it back and restart. If it is gone, everyone signs in again and any secrets the interface had encrypted, such as saved payment gateway credentials, have to be entered again.
TIP
Include .oempro_env in your backups. It holds this key.
Some numbers on a list screen look wrong
A small number of screens in the list area are not yet connected to live data and show placeholder figures. If a figure looks implausible on a list screen and everything else on the account is consistent, this is the likely explanation rather than a data problem. This is known and is being worked on.
Getting more detail
Turn the log level up temporarily:
UI_LOG_LEVEL=debugRestart the interface container, reproduce the problem, then read the log:
docker logs oempro_ui 2>&1 | tail -100WARNING
Set it back to error afterwards. Debug logging is verbose and can fill a disk on a busy install.